Call Us : +91 :9822008747

Fire Sprinkler System


A fire sprinkler system is an active fire protection method, and Efficient Fire & Security Solutions believe in a fire fighting system that provides maximum safety and detection and immediate fire suppression before turning it into any major hazard for humans and property.
A sprinkler system consists of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected, located at the ceiling level or wall-mounted or in case water spray directly mounted on an external piping system. With the effect of fire at the site, due to the rise in heat, the predetermined temperature (generally greater than 40-degree Celcius) reaches causing a glass component in sprinkler head to fail to result in the discharge of water spray from a sprinkler head.
Fire Sprinkler system is so successful in extinguishing the fire, in buildings completely protected by fire sprinkler systems, over 96% of fires were controlled by fire sprinklers alone because this efficiency these systems are used ubiquitously as fire worldwide, with over 40 million sprinkler heads implemented each year. Choose the best fire sprinkler system from following for fire protection.


Wet pipe fire sprinkler system


A wet pipe fire sprinkler system is the most common type of sprinkler system employing automatic sprinkler heads attached to a piping system containing pressured water and connected to a water supply so that water discharges immediately from sprinklers opened by heat from a fire. Learn more about the wet pipe fire sprinkler system.


Product Details:


Rate of Speed 300 rpm
Flash points Below 32 Degree Celsius
Body Material Carbon Steel
Sprinkler Type Pendant
Working Pressure 12-14 bar
Discharge Area 20-25 Meter
Jet Range 4-12 sec
Flow Rate 10 to 20 Liter/Hours
Nominal Diameter 40 mm
Mounting Type Ceiling, wall
Usage/Application Office, Shopping Mall, Office, Factory, Residential, Commercial

Dry pipe fire sprinkler system


Dry pipe fire sprinkler systems are specially designed for environments with freezing temperatures like walk-in refrigerators, loading docks, and warehouses, buildings susceptible to freezing, dry pipe sprinkler systems feature automatic and closed-type sprinkler heads connected to pipes filled with pressurized air or nitrogen. The compressed air holds a remote valve, known as a dry pipe valve, in a closed position to prevent water from entering the pipe. When heat activates one or more sprinklers, the compressed air in the pipe is released, and its pressure decreases, opening the dry pipe valve and allowing water to flow through open sprinklers.


Product Details:


delay Time upto 60 sec
Flash points Below 32 Degree Celsius
Body Material Carbon Steel
Sprinkler Type Pendant
Installation Temp. Above 4 degree Celsius
Working Pressure 12-14 bar
Discharge Area 20-25 Meter
Jet Range 4-12 sec
Flow Rate 10 to 20 Liter/Hours
Nominal Diameter 40 mm
Mounting Type Ceiling, wall
Usage/Application Loading docks, warehouses

Deluge fire sprinkler system


Product Details:


Fire Suppression Type water, dry chemicals, inert gases, or foam
Fire alarm initiating device pilot sprinklers, smoke & heat detectors, optical flame detectors, etc
Sprinkler Type Open Head
Manual activation Through Electric or pneumatic fire alarm pull station
Body Material Carbon Steel
Usage/Application Chemical Plants, Processing Plants, Airport Hangars, Data Storage Units

Pre-action fire sprinkler system


Product Details:


Mounting Type 90/180 degree Pattern inlet to outlet vertical Mounting
Working Pressure 175 - 300 PSI
Nominal Diameter 100/150/200mm dia
Min. Operating Pressure 0.5 bar
Flow Rate 60Lpm to 450Lpm
Design Standard As per NFPA-13
Response 68/79 Deg Celsius
Alarm Density 0.65- 1.55 % FT
Alarm volume Distance 85 DB in 3-meter
Connection Type Flanged / Grooved End
Factory Hydrostatic Test 175 psi
Frame Material Brass/chrome finish
Nominal K-Factor 80/115
Flange Connection ANSI B 16.1 FF #125
Trim Galvanized Steel with Brass Valves
Usage/Application Environments that are sensitive to water - Museums,Data Cente,Libraries

Foam water fire sprinkler systems


Product Details:

Fire Suppression Type Water used with chemical foam
Sprinkler Type Pendent, Upright
Temperature Response 57-93 degree Celsius
Coverage 9mtr minimum
K-Factor 80 and above
Thread Types NPT/BSPT
Max. Working Pressure 12 bar
Min. Operating Pressure 0.5 Bar
Temp. Rating 0- 50 Deg.C
Usage/Application power plants, off shore oil rigs, aircraft hangars and chemical storage or processing facilities

Water Spray fire sprinkler systems


Product Details:

Temperature Range -40 to 80 Deg Celsious
Flash points Below 32 Degree
Body Material Cast Iron
Weight Varies from 1 kg to 25 kg
Finishing Color Coated
Mounting Type Side Wall, Upright
Water Spray Velocity Medium, High
Standards & Compliance TAC, NFPA
Usage/Application Vessels and other structures which are exposed to heat

Water mist fire sprinkler systems


Product Details:

Intermediate pressure 175 psi and 500 psi
high pressure systems 500 psi and up
Nozzle Type 1,000 microns in diameter